EUROX® Measurement-Systems

EXTRACTIVE MEASUREMENT SYSTEM FOR GLASS CONDITIONING SYSTEMS

GENERAL

The EUROX® FH-System extractive measurements on glass conditioning systems is very reliable also in near stoichiometric conditions. The gas to be investigated is heated up and catalytically decomposed. After reaction the oxygen content is measured at equilibrium and converted.

APPLICATION

Up to 12 heating zones can be observed and analysed with one EUROX® FH-System.

EUROX® FH-System includes a solenoid valve unit for switching between the connected heating zones and a measuring unit including an OM 4 multifunctional unit for evaluation, controlling and visualisation. The measuring system can be connected with the PLC so controlling and visualisation can also be done via PLC.

EVALUATION

Visualisation of EUROX® FH-System is done via visualisation unit of OM-4 and via PLC. Evaluation is also done via OM-4 multifunctional unit. Adapted to the application and number of observed heating zones, all evaluated values are presented.

The following evaluations can be offered:

SENSOR TEMPERATURE IN °C, CELL VOLTAGE IN mV

  • Standard values of the measurement
  • Output from sensor

LAMBDA

  • Lambda value of the actual combustion condition when firing the premixed gas
  • Basis for measurement evaluation

 O2 CONTENT IN PREMIXED GAS IN %

  • Calculated oxygen content in the premixed gas before firing

MEMORY MODULE

  • Internal memory that gives the measurement a memory to detect long-term trends or drifts and to compare the current readings with values from the past

SELF-CHECK MODULE

  • Various internal checks and monitored values to prevent malfunctions of the measuring system

 

BENEFITS

A stable combustion condition is important for glass conditioning, otherwise problems with glass quality or colour may occur. So, for example changing fuel gas compositions can lead to problems.

With the EUROX® FH system the premixed fuel gas/air mixture is analysed and evaluated, so a stable combustion condition can be achieved. The system is available as a stand-alone and add-on system to a HORN SCADA system and can be offered as purchase offer or rental- and service.

 

FEATURES

  • Protection of measuring cell through diffusion block
  • Stable structure and low maintenance
  • Lifespan up to ten years depending on conditions
  • Quick response and high precision also in near stoichiometric conditions
  • Fast installation
  • Determination of the Lambda value and the O2 content of the premix

CONTACT

Do you have any questions? Then please do not hesitate to contact us.

CONTACT US